The rule of thumb for foil faced boards like thermapitch tp10 or kooltherm k7 in this scenario is that you can have no more insulation under the joists than you have between the joists.
Cold flat roof insulation between joists.
Poly to the underside of joists.
How to insulate a flat roof.
This quetion is to do with warm roofs and cold roofs presumably the 50mm of insulation on the underside of joists would act as the vapour barrier if taped sealed correctly or if insulation between joists a vapour barrier i e.
As there are two types of flat roofs available that require different types of insulation the methods used.
It allows insulation to be added without having to replace the waterproofing on.
Refurbishing an existing timber joisted flat roof which has no insulation.
The underside of the rafters in this case will need to be finished with a suitable vapour control layer vcl and plasterboard to provide a suitable internal finish to the roof.
Insulation is placed in between the joists underneath the roof surface above.
In the warm flat roof construction there is insulation packed into every possible space where air can flow.
The insulation is below the deck but above the plasterboard.
Where insulation depth is restricted by the flat roof construction it may be necessary to install the roof insulation between and below the joists to create a cold deck structure.
Cold deck roof a cold deck roof is where the insulation is placed between the joists rafters or in between the ceiling joists in the case of a pitch roof.
Creating a void between the old ceiling and new is better but ideally you need to eventually consider insulating the top of the concrete roof with solid insulation and a better.
This is used for refurbishment e g.
The majority of domestic cold flat roofs use insulation between and under the joists.
A warm deck roof is where the insulation is placed on top of the rafters joists and the roof covering is then placed over the insulation.
No ventilation is required for these types of roofs.
A cold flat roof is one where the insulation is between or between and below the roof joists.
This method of insulation can also be used to upgrade the thermal performance of an existing roof without affecting the waterproofing system.
Both these variants require different approaches to insulation which will be covered in this guide.
Great videos thanks for sharing.
Alternatively battens can be secured to the underside of the joists and gmw fitted between these in much the same way as between the main roof joists.