Residential code section r404 4 specifies that retaining walls shall be designed to ensure.
City of los angeles standard retaining wall detail.
Informational page for pre approved standard plans.
Retaining or slough wall 4 foot high or less 178 kb view.
County of los angeles department of public works building and safety division based on the 2011 lacrc 1014 r404 4 article 1 10 25 12 page 1 of 7 design of retaining walls issue.
If any information on any of the standard plans is not legible it is the user s responsibility to obtain a legible copy from the bureau of engineering vault located at.
6 concrete block masonry wall detail 6 0 height maximum general specifications.
Concrete block units to be staggered running bond.
San diego municipal code chapter 14 article 2.
Retaining walls heights are also regulated by the zoning laws of the city as follows.
213 847 0700.
Build safe well and fast with the city of los angeles department of building and safety.
City of los angeles electrical plan check correction list.
1149 s broadway suite b 10 los angeles ca 90015 phone.
As a covered entity under title ii of the americans with disabilities act the city of los angeles does not discriminate on the basis of disability and upon request will provide reasonable accommodation to ensure equal access to its programs services and activities.
Reinforcing steel shall be deformed steel conforming to a s t m.
Concrete block units shall conform to astm c90.
Acceptable engineering criteria for retaining wall design.
Concrete block units to be standard 8 x8 x16 units conforming to ubc standard 21 4.
Disabled access standard details notes for commercial buildings.
Concrete block retaining wall h 6 0 max b3761 1 b3761 2.
Soil lateral loads labc 1610 1 general.
Page 1 of 2 retaining or slough wall 4 0 high or less.
Each series contains several standard plans.
City of los angeles electrical plan check correction list.
Back to standard plans main index.
Concrete mix for footing to be 1 part cement to 2 5 parts sand to 3 5 parts gravel with a maximum of 7 5 gallons of water per sack of cement minimum f c 2 500 psi.
Metal bin type retaining wall.
Alternative design procedures justified in a geotechnical report may also be approved.
Design of retaining walls as presented in this bulletin are in accordance with sections 1610 1 and 1807 2 of the city of los angeles building code labc.
The height of a retaining wall is measured from grade on the lower side of the retaining wall to the top of the retaining wall exposed height e sdmc 113 0270 b 2.
Lap all steel 16.
The standard plans are divided into several series.